This is a Demo Server. Data inside this system is only for test purpose.
 

Spectroscopic determination of industrial oil blends using multivariate calibraton

dc.contributor.advisor Özdemir, Durmuş en
dc.contributor.author Yalçın, Ayşegül
dc.date.accessioned 2023-11-13T09:08:18Z
dc.date.available 2023-11-13T09:08:18Z
dc.date.issued 2009 en
dc.description Thesis (Master)--İzmir Institute of Technology, Chemistry, İzmir, 2009 en
dc.description Includes bibliographical references (leaves: 104-106) en
dc.description Text in English; Abstract: Turkish and English en
dc.description xv, 106 leaves en
dc.description.abstract This study focuses on the development of multivariate calibration models for the aluminum rolling oil additives and contaminants using Fourier Transform Infrared (FTIR) spectroscopy and a genetic algorithm based inverse least squares (GILS) method. Multivariate calibration models were generated for both synthetic mixtures and real process samples taken from an industrial aluminum production plant. Two different additives and six different suspected contaminants were investigated in the base oil lubricant. Gas chromatography (GC) was used for the analysis of real process samples in order to establish reference values of additives and contaminants in the base rolling oil. FTIR spectra of real samples together with the reference values established with GC analysis were used to generate multivariate calibration models. GC analysis revealed that most of the contaminants gave overlapped chromatograms and therefore only the total contamination was determined with reference GC analysis. On the other hand, FTIR spectroscopy coupled with multivariate calibration was able to resolve overlapping components with synthetic samples. The reference values for both additives and contaminants obtained by GC were compared with the results of the spectroscopic analysis. The multivariate calibration models based on spectroscopic data validated with the real process samples in a period of twelve months, however only a set of 3-month data is given in this thesis. The R2 values between GC and multivariate spectroscopic determinations were around 0.99 indicating a good correlation between the two methods. en
dc.identifier.uri http://standard-demo.gcris.com/handle/123456789/3736
dc.language.iso en en_US
dc.publisher Izmir Institute of Technology en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject.lcc TP685 .Y16 2009 en
dc.subject.lcsh Mineral oils--Analysis en
dc.subject.lcsh Infrared spektroscopy en
dc.subject.lcsh Gas chromatography en
dc.subject.lcsh Calibration en
dc.title Spectroscopic determination of industrial oil blends using multivariate calibraton en_US
dc.type Master Thesis en_US
dspace.entity.type Publication
gdc.author.institutional Yalçın, Ayşegül
gdc.description.department Computer Engineering en_US
gdc.description.publicationcategory Tez en_US