This is a Demo Server. Data inside this system is only for test purpose.
 

Dynamic energy and exergy analysis of an existing building in IZTECH

dc.contributor.advisor Başaran, Tahsin en
dc.contributor.author Akdemir, Manolya
dc.date.accessioned 2023-11-13T09:43:34Z
dc.date.available 2023-11-13T09:43:34Z
dc.date.issued 2013 en
dc.description Thesis (Master)--Izmir Institute of Technology, Energy Engineering, Izmir, 2013 en
dc.description Includes bibliographical references (leaves: 97-99) en
dc.description Text in English; Abstract: Turkish and English en
dc.description xii, 99 leaves en
dc.description.abstract Primary objective of this thesis is to find out energy level of an existing building and investigate the opportunities in order to improve its energy level by retrofitting the envelope and using exergy analysis methods on alternative HVAC systems. To arrive at the objective, an existing building, Izmir Institute of Technology (IZTECH), Faculty of Architecture Block C, has been used as the case study. This building cannot comply with TS-825 standards (Turkish Standard Assessment) and energy efficiency parameters due to the building components and HVAC systems. According to the recorded outdoor climatic conditions, the building was modeled and simulated; and the retrofitting was tried in EDSL-TAS energy simulation software package. Simultaneously, exergy analyses for the situations before and after refurbishments were employed. Different from the most studies in the literature, this thesis carries out the exergy analyses using the dynamic data instead of the steady state ones. By the evaluation of these analyses together, energy level and the climatic comfort of the building have been seriously increased and the building’s loads have been decreased with ratio of 69.42% for heating system and 34.4% for cooling system after retrofitting. In exergy calculations, exergy efficiency of the system ranges between 2-14% with existing HVAC applications, 4-18% with Air Source Heat Pump (ASHP) and 8-21% with Ground Source Heat Pump (GSHP). en
dc.identifier.uri http://standard-demo.gcris.com/handle/123456789/5106
dc.language.iso en en_US
dc.publisher Izmir Institute of Technology en
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject.lcsh Buildings--Energy conservation en
dc.subject.lcsh Exergy en
dc.title Dynamic energy and exergy analysis of an existing building in IZTECH en_US
dc.type Master Thesis en_US
dspace.entity.type Publication
gdc.author.institutional Akdemir, Manolya
gdc.description.department Computer Engineering en_US
gdc.description.publicationcategory Tez en_US
gdc.oaire.accepatencedate 2013-01-01
gdc.oaire.diamondjournal false
gdc.oaire.impulse 0
gdc.oaire.influence 2.9837197E-9
gdc.oaire.influencealt 0
gdc.oaire.isgreen true
gdc.oaire.keywords Energy
gdc.oaire.keywords Engineering Sciences
gdc.oaire.keywords Enerji
gdc.oaire.keywords Mühendislik Bilimleri
gdc.oaire.popularity 9.2213404E-10
gdc.oaire.popularityalt 0.0
gdc.oaire.publicfunded false