Numerical study of enhancement of plastic rotation capacity of seismic steel moment connections by fiber reinforced polymer materials

dc.contributor.advisor Eğilmez, Oğuz Özgür en
dc.contributor.author Alkan, Deniz
dc.date.accessioned 2023-11-13T09:45:48Z
dc.date.available 2023-11-13T09:45:48Z
dc.date.issued 2008 en
dc.description Thesis (Master)--Izmir Institute of Technology, Civil Engineering, Izmir, 2008 en
dc.description Includes bibliographical references (leaves: 78-82) en
dc.description Text in English; Abstract: Turkish and Enlish en
dc.description xi, 93 leaves en
dc.description.abstract Flange and web local buckling in beam plastic hinge regions of welded Steel Moment Frames (SMF) can prevent the beam-column connections to achieve adequate plastic rotations under earthquake induced forces. Reducing the web-flange slenderness ratios is the most effective way in preventing local member buckling as stipulated in the latest earthquake specifications. However, older steel beam-column connections that lack the adequate slenderness ratios stipulated for new SMFs are vulnerable to local plastic buckling. This study investigates postponing the formation of local buckles in beam flanges and webs at the plastic hinge region of modified SMF connections (welded haunch) by the use of externally bonded Glass Fiber Reinforced Polymers (GFRP). The research includes finite element (FE) modeling. The energy dissipation capacity of existing SMF connections is anticipated to increase with GFRP laminates bonded to flanges of beams in plastic hinge locations. Cantilever beams with and without GFRP were analyzed under quasi-static cyclic loading and the effects to the plastic local buckling of the GFRP laminates added to the steel beams were observed.Both geometric and material nonlinearities are considered. The mechanical properties of the GFRP material were obtained through standard ASTM tests and were utilized directly in the FE model. Steel beams with flange slenderness ratios of 8 to 12 and web slenderness ratios of 40-60-80 were analyzed. Results indicate that GFRP strips can effectively delay the formation of local plastic buckling in the plastic hinge region. en
dc.identifier.uri http://standard-demo.gcris.com/handle/123456789/5256
dc.language.iso en en_US
dc.publisher Izmir Institute of Technology en
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject.lcc TA890. A415 2008 en
dc.subject.lcsh Steel, Structural en
dc.subject.lcsh Fiber reinforced plastic--Joints en
dc.subject.lcsh Polymers en
dc.title Numerical study of enhancement of plastic rotation capacity of seismic steel moment connections by fiber reinforced polymer materials en_US
dc.type Master Thesis en_US
dspace.entity.type Publication
gdc.author.institutional Alkan, Deniz
gdc.description.department Materials Science and Engineering en_US
gdc.description.publicationcategory Tez en_US
gdc.oaire.accepatencedate 2008-01-01
gdc.oaire.diamondjournal false
gdc.oaire.impulse 0
gdc.oaire.influence 2.9837197E-9
gdc.oaire.influencealt 0
gdc.oaire.isgreen true
gdc.oaire.keywords Mechanical Engineering
gdc.oaire.keywords Makine Mühendisliği
gdc.oaire.keywords İnşaat Mühendisliği
gdc.oaire.keywords Civil Engineering
gdc.oaire.popularity 5.4090155E-10
gdc.oaire.popularityalt 0.0
gdc.oaire.publicfunded false

Files

Collections