This is a Demo Server. Data inside this system is only for test purpose.
 

Energy performance analysis of Adnan Menderes International Airport (ADM)

dc.contributor.advisor Özkol, Ünver en
dc.contributor.author Ceyhan Zeren, Fatma Tuba
dc.date.accessioned 2023-11-13T09:32:19Z
dc.date.available 2023-11-13T09:32:19Z
dc.date.issued 2010 en
dc.description Thesis (Master)--Izmir Institute of Technology, Energy Engineering, Izmir, 2010 en
dc.description Includes bibliographical references (leaves: 50-51) en
dc.description Text in English; Abstract: Turkish and English en
dc.description x, 55 leaves en
dc.description.abstract Space cooling and heating are needed throughout the year for commercial buildings and electricity use in these buildings accounts for about one-third of the total energy consumption in Turkey. In this study, Adnan Menderes International Airport (ADM) located in Izmir is simulated with EnergyPlus software which is a new generation building energy analysis tool. The simulation model is constructed first with Design Builder and than the measured data are used to compare the model. EnergyPlus simulations are used in this thesis to help understanding more about the ADM.s dynamics and evaluate various strategies such as different orientation and heating, cooling, ventilation and air conditioning (HVAC) system. According to simulation and different HVAC system results; cooling electricity consumption increases 2.8 times in each month. According to simulation and east orientation results, heat gains decrease between 2% and 11% in winter, autumn and spring months and increase between 3% and 14% in summer months. Measured data of ADM building showed that HVAC system had constituted almost 80% of the total energy consumption, according to the average data obtained in 2008. The difference between measured and simulation consumption values are greater more than 70%. According to simulation results, also there is 2.4 times more electricity consumption on 18 August when compared to 11 January. Finally, analysis showed that ADM building requires year-round cooling and very little heating. en
dc.identifier.uri http://standard-demo.gcris.com/handle/123456789/4482
dc.language.iso en en_US
dc.publisher Izmir Institute of Technology en
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject.lcsh Buildings--Energy conservation en
dc.subject.lcsh Heating and ventilating industry en
dc.subject.lcsh Energy conservation--Evaluation en
dc.title Energy performance analysis of Adnan Menderes International Airport (ADM) en_US
dc.type Master Thesis en_US
dspace.entity.type Publication
gdc.author.institutional Ceyhan Zeren, Fatma Tuba
gdc.description.department Conservation and Restoration of Cultural Heritage en_US
gdc.description.publicationcategory Tez en_US
gdc.oaire.accepatencedate 2010-01-01
gdc.oaire.diamondjournal false
gdc.oaire.impulse 0
gdc.oaire.influence 2.9837197E-9
gdc.oaire.influencealt 0
gdc.oaire.isgreen true
gdc.oaire.keywords Energy
gdc.oaire.keywords Airports
gdc.oaire.keywords Enerji
gdc.oaire.keywords Energy analysis
gdc.oaire.keywords Simulation
gdc.oaire.popularity 6.5821576E-10
gdc.oaire.popularityalt 0.0
gdc.oaire.publicfunded false

Files