This is a Demo Server. Data inside this system is only for test purpose.
 

Monitoring and assessment of indoor air volatile organic compound concentrations in primary schools

No Thumbnail Available

Date

2008

Journal Title

Journal ISSN

Volume Title

Publisher

Izmir Institute of Technology
Izmir Institute of Technology

Open Access Color

Green Open Access

Yes

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No

Research Projects

Organizational Units

Journal Issue

Abstract

Indoor air quality (IAQ) is important mainly because, poor IAQ may cause variety of adverse health effects and people spend majority of their time indoors. One of the most susceptible groups to air pollution is considered as children. Children spend approximately six to eight hours a day in school buildings, therefore the indoor air quality of school buildings should be given utmost importance. Formaldehyde and volatile organic compounds (VOCs) have been receiving considerable interest in indoor air field studies because of their high emission rates from products used indoor environments. Thus, their concentrations have been measured in school buildings in many different countries.Indoor and outdoor air samples were collected from three primary schools in İzmir (School 1, School 2, and School 3). Sampling was performed in spring and winter terms. Active sampling was applied for VOCs and formaldehyde by using Tenax TA and DNPH silica gel sorbent tubes, respectively. VOCs were analyzed by using a thermal desorption - gas chromatography - mass spectrometry (TD-GC-MS) system.Formaldehyde analysis was performed by using an HPLC instrument.Benzene, toluene, ethyl benzene and xylenes, which have high toxicity, were detected at high concentrations. In addition, the indoor/outdoor (I/O) concentration ratios of VOCs were investigated. Mean Total VOC (TVOC) and formaldehyde concentrations were calculated for the three schools in winter and spring terms. TVOC and formaldehyde concentrations were 104 .g/m3 and 44.36 ./m3 in winter, and 66.42 .g/m3 and 43.73 .g/m3 in spring terms for School 1; and 50.86 .g/m3 and 30.78 .g/m3 in winter, and 32.1 .g/m3 and 35.82 .g/m3 in spring term for School 2, and 51.09 .g/m3 and 36.53 .g/m3 in spring term for School 3 primary schools, respectively. These concentration values are generally higher than or parallel to the values reported in the literature. The TVOC concentrations in kindergartens were higher than the concentrations in classrooms.

Description

Thesis (Master)--Izmir Institute of Technology, Chemical Engineering, Izmir, 2008
Includes bibliographical references (leaves: 102-111)
Text in English; Abstract: Turkish an English
xi, 111 leaves

Keywords

TD883.17 A835 2008, Chemical Engineering, Kimya Mühendisliği

Turkish CoHE Thesis Center URL

Fields of Science

Citation

WoS Q

Scopus Q

Source

Volume

Issue

Start Page

End Page

Collections

Google Scholar Logo
Google Scholar™

Sustainable Development Goals