This is a Demo Server. Data inside this system is only for test purpose.
 

Acoustic indoor localization employing code division multiple access

dc.contributor.advisor Altınkaya, Mustafa Aziz en
dc.contributor.author Sertatıl, Cem
dc.date.accessioned 2023-11-13T09:22:47Z
dc.date.available 2023-11-13T09:22:47Z
dc.date.issued 2010 en
dc.description Thesis (Master)--Izmir Institute of Technology, Electronics and Communication Engineering, Izmir, 2010 en
dc.description Includes bibliographical references (leaves: 107-108) en
dc.description Text in English; Abstract: Turkish and English en
dc.description xvi, 160 69 leaves en
dc.description.abstract Indoor localization becomes a demand that comes into prominence day by day. Although extensively used outdoor location systems have been proposed, they can not operate in indoor applications. Hence new investigations have been carried on for accurate indoor localization in the last decade. In this thesis, a new indoor location system, that aims to locate an entity within an accuracy of about 2 cm using ordinary and inexpensive off-the-shelf devices, has been proposed and an implementation has been applied to evaluate the system performance. Therefore, time of arrival measurements of acoustic signals, which are binary phase shift keying modulated Gold code sequences using direct sequence spread spectrum technique, are done. Direct sequence-code division multiple access is applied to perform simultaneous accurate distance measurements and provides immunity to noise and interference. Two methods have been proposed for the location estimation. The first method takes the average of four location estimates obtained by trilateration technique. In the second method, only a single robust position estimate is obtained using three distances while the least reliable fourth distance measurement is not taken into account. The system performance is evaluated at positions from two height levels using two sets of variables determined by experimental results. The precision distributions in the work area and the precision versus accuracy plots depict the system performance for different sets of variables. The proposed system provides location estimates of better than 2 cm accuracy within 99% precision. Eventually, created graphical user interface provides a user friendly environment to adjust the parameters. en
dc.identifier.uri http://standard-demo.gcris.com/handle/123456789/4006
dc.language.iso en en_US
dc.publisher Izmir Institute of Technology en
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject.lcsh Location-based services en
dc.title Acoustic indoor localization employing code division multiple access en_US
dc.type Master Thesis en_US
dspace.entity.type Publication
gdc.author.institutional Sertatıl, Cem
gdc.description.department Food Engineering en_US
gdc.description.publicationcategory Tez en_US
gdc.oaire.accepatencedate 2010-01-01
gdc.oaire.diamondjournal false
gdc.oaire.impulse 0
gdc.oaire.influence 2.9837197E-9
gdc.oaire.influencealt 0
gdc.oaire.isgreen true
gdc.oaire.keywords Elektrik ve Elektronik Mühendisliği
gdc.oaire.keywords Electrical and Electronics Engineering
gdc.oaire.popularity 6.5821576E-10
gdc.oaire.popularityalt 0.0
gdc.oaire.publicfunded false