This is a Demo Server. Data inside this system is only for test purpose.
 

The use of cell polyurethane foams in air-type solar collectors as the heat absorbing element

No Thumbnail Available

Date

2006

Journal Title

Journal ISSN

Volume Title

Publisher

Izmir Institute of Technology

Open Access Color

Green Open Access

Yes

OpenAIRE Downloads

17

OpenAIRE Views

20

Publicly Funded

No

Research Projects

Organizational Units

Journal Issue

Abstract

After the energy crisis in early 1970.s, the priority of alternative energy resources is expanded. There have been many researches, to increase the efficiency of solar energy utilization systems, for domestic and industrial usage since early 1980.s up to now. In many fields air-type solar collectors are applicable. They generally used in food industry to dry agricultural products, textile industry to dry fabrics and space heating. Drying grains (wheat, barley, maize, etc.), fruits (grape, fig, apricot etc.), vegetables, tea are examples for food industry. Greenhouse heating and hospital heating to obtain fresh air are examples of space heating. These examples show that improving their performance is indispensable for commercial acceptance. In this study, the open-cell polyurethane foam as an absorber material, placed in a south facing, flat plate air-type solar collector at fixed tilt angle and effect of this material on collector efficiency has been investigated. The collector designed specially, in order to get maximum heat gain from the useful solar intensity falling on the glazing and insulated to loose minimum heat from collector case and transfer channels. Collector is tested under the regulations of ASHRAE 93-1986 standard named .Methods of Testing to Determine The Thermal Performance of Solar Collectors.. Air passing through the collector has been provided by a fan. Tests are repeated with three air speeds 1.266 m/s, 1.5825 m/s and 1.899 m/s. Maximum average efficiency is calculated on 1.5825 m/s. Maximum average temperature difference of air between inlet and outlet sections observed on 1.266 m/s. Maximum outlet temperature that we get is on the same day with maximum average temperature difference.

Description

Thesis (Master)--Izmir Institute of Technology, Energy Engineering, Izmir, 2006
Includes bibliographical references (leaves: 60-62)
Text in English, Abstract: Turkish and English
xiv, 109 leaves

Keywords

Turkish CoHE Thesis Center URL

Fields of Science

Citation

WoS Q

Scopus Q

Source

Volume

Issue

Start Page

End Page

Collections

Google Scholar Logo
Google Scholar™

Sustainable Development Goals