This is a Demo Server. Data inside this system is only for test purpose.
 

Analytical and numerical sensitivity analysis of constant temperature hot-wire anemometre

dc.authoridTR191337en_US
dc.contributor.advisorÖzkol, Ünver
dc.contributor.authorUz, Yusuf Can
dc.date.accessioned2023-11-13T09:30:53Z
dc.date.available2023-11-13T09:30:53Z
dc.date.issued2014
dc.departmentMechanical Engineeringen_US
dc.descriptionThesis (Master)--Izmir Institute of Technology, Mechanical Engineering, Izmir, 2014en_US
dc.descriptionIncludes bibliographical references (leaves: 78-79)en_US
dc.descriptionText in English; Abstract: Turkish and Englishen_US
dc.descriptionxiv, 79 leavesen_US
dc.description.abstractHot-wire anemometry (HWA) has been used for many years as a research tool in fluid mechanics. HWA consists of a wire sensor, a very fine element exposed to the fluid flow and of an electronic system, which performs the transformation of the sensor output into a useful electric signal. HWA is based on convective heat transfer from a heated wire which is placed into a fluid flow. The heat is generated inside the very fine wire owing to wire resistance when electrical current passes through it. Then, the wire will be subjected to heat losses by convection, conduction and radiation depending on the flow condition. To examine the theory of operation for the heated wire and plot the temperature distribution along it, energy balance for HWA is investigated by taking differential element of dx length of the filament. In order to understand static and dynamic characteristics of hot-wire, all kinds of heat transfer such as convection, conduction and radiation are taken into consideration. In present thesis, the static study starts to investigate influence of the sensor parameters on general behavior of the constant temperature hot-wire anemometer analytically and numerically at varying conditions. Most important part of this study is that the time dependent differential equation for the heated wire is solved to determine sensitivity of hot-wire by a perturbation method in the event of a harmonically changing heat transfer coefficient. Moreover, the influence of thin supporting wires, or copper plated wire ends, is evaluated to see the effects of them on sensitivity and heat dissipation to the prongs. Another important parameter for wire sensor is the aspect ratio (L/d). Aspect ratio affects the time constant, sensitivity and temperature distribution of heated wire; hence it needs to be examined. Also, effect of the various velocities on the temperature distribution and sensitivity along the hot-wire has been studied.en_US
dc.identifier.urihttp://standard-demo.gcris.com/handle/123456789/4406
dc.institutionauthorUz, Yusuf Can
dc.language.isoenen_US
dc.oaire.dateofacceptance2014-01-01
dc.oaire.impulse0
dc.oaire.influence2.9837197E-9
dc.oaire.influence_alt0
dc.oaire.is_greentrue
dc.oaire.isindiamondjournalfalse
dc.oaire.keywordsMechanical Engineering
dc.oaire.keywordsMakine Mühendisliği
dc.oaire.popularity1.0422565E-9
dc.oaire.popularity_alt0.0
dc.oaire.publiclyfundedfalse
dc.publisherIzmir Institute of Technologyen_US
dc.relation.publicationcategoryTezen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subject.lcshHot-wire anemometeren_US
dc.subject.lcshFluid dynamic measurementsen_US
dc.subject.lcshHeat--Transmission--Measurementen_US
dc.titleAnalytical and numerical sensitivity analysis of constant temperature hot-wire anemometreen_US
dc.title.alternativeSabit sıcaklık sıcak tel anemometre hassasiyetinin analitik ve nümerik analizien_US
dc.typeMaster Thesisen_US
dspace.entity.typePublication

Files

Collections