This is a Demo Server. Data inside this system is only for test purpose.
 

Analytical and numerical sensitivity analysis of constant temperature hot-wire anemometre

dc.authorid TR191337 en_US
dc.contributor.advisor Özkol, Ünver
dc.contributor.author Uz, Yusuf Can
dc.date.accessioned 2023-11-13T09:30:53Z
dc.date.available 2023-11-13T09:30:53Z
dc.date.issued 2014
dc.department Mechanical Engineering en_US
dc.description Thesis (Master)--Izmir Institute of Technology, Mechanical Engineering, Izmir, 2014 en_US
dc.description Includes bibliographical references (leaves: 78-79) en_US
dc.description Text in English; Abstract: Turkish and English en_US
dc.description xiv, 79 leaves en_US
dc.description.abstract Hot-wire anemometry (HWA) has been used for many years as a research tool in fluid mechanics. HWA consists of a wire sensor, a very fine element exposed to the fluid flow and of an electronic system, which performs the transformation of the sensor output into a useful electric signal. HWA is based on convective heat transfer from a heated wire which is placed into a fluid flow. The heat is generated inside the very fine wire owing to wire resistance when electrical current passes through it. Then, the wire will be subjected to heat losses by convection, conduction and radiation depending on the flow condition. To examine the theory of operation for the heated wire and plot the temperature distribution along it, energy balance for HWA is investigated by taking differential element of dx length of the filament. In order to understand static and dynamic characteristics of hot-wire, all kinds of heat transfer such as convection, conduction and radiation are taken into consideration. In present thesis, the static study starts to investigate influence of the sensor parameters on general behavior of the constant temperature hot-wire anemometer analytically and numerically at varying conditions. Most important part of this study is that the time dependent differential equation for the heated wire is solved to determine sensitivity of hot-wire by a perturbation method in the event of a harmonically changing heat transfer coefficient. Moreover, the influence of thin supporting wires, or copper plated wire ends, is evaluated to see the effects of them on sensitivity and heat dissipation to the prongs. Another important parameter for wire sensor is the aspect ratio (L/d). Aspect ratio affects the time constant, sensitivity and temperature distribution of heated wire; hence it needs to be examined. Also, effect of the various velocities on the temperature distribution and sensitivity along the hot-wire has been studied. en_US
dc.identifier.uri http://standard-demo.gcris.com/handle/123456789/4406
dc.institutionauthor Uz, Yusuf Can
dc.language.iso en en_US
dc.oaire.dateofacceptance 2014-01-01
dc.oaire.impulse 0
dc.oaire.influence 2.9837197E-9
dc.oaire.influence_alt 0
dc.oaire.is_green true
dc.oaire.isindiamondjournal false
dc.oaire.keywords Mechanical Engineering
dc.oaire.keywords Makine Mühendisliği
dc.oaire.popularity 1.0422565E-9
dc.oaire.popularity_alt 0.0
dc.oaire.publiclyfunded false
dc.publisher Izmir Institute of Technology en_US
dc.relation.publicationcategory Tez en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject.lcsh Hot-wire anemometer en_US
dc.subject.lcsh Fluid dynamic measurements en_US
dc.subject.lcsh Heat--Transmission--Measurement en_US
dc.title Analytical and numerical sensitivity analysis of constant temperature hot-wire anemometre en_US
dc.title.alternative Sabit sıcaklık sıcak tel anemometre hassasiyetinin analitik ve nümerik analizi en_US
dc.type Master Thesis en_US
dspace.entity.type Publication

Files