This is a Demo Server. Data inside this system is only for test purpose.
 

Use of amine-and mercapto-modified silica as soild phase extraction sorbent for speciation of inorganic selenium prior to determination by atomic spectrometric techniques

No Thumbnail Available

Date

2010

Journal Title

Journal ISSN

Volume Title

Publisher

İzmir Institute of Technology
Izmir Institute of Technology

Open Access Color

Green Open Access

Yes

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No

Research Projects

Organizational Units

Journal Issue

Abstract

Silica-based sorbents containing amino-, mercapto-, and both functional groups (bifunctional) were prepared and used for the sorption of inorganic Se(IV) and Se(VI) species from waters prior to their determination by atomic spectrometric techniques, namely, inductively coupled plasma mass spectrometry (ICP-MS) and hydride generation atomic absorption spectrometry (HGAAS). The presence of the functional groups on the surface of the silica was demonstrated by using several characterization techniques such as scanning electron microscopy (SEM), solid-state NMR spectroscopy, thermo gravimetric analysis (TGA), elemental analysis and Brunauer-Emmett-Teller (BET) surface area analysis. Amine-modified silica was found to be selective towards Se(VI) at pHs 2.0 and 3.0 whereas mercapto-modified silica retains Se(IV) over a wide range from acidic regions to pH 4.0. Bifunctional silica, on the other hand, possesses the good features of the two sorbents; it can be used in the separate sorption of Se(IV) or of both Se(IV) and Se(VI) species. Acidic pHs (<1.0) are convenient for the sorption of Se(IV) alone where no sorption is observed for Se(VI). Alternatively, pH can be adjusted to 2.0 or 3.0 and Se(IV) and Se(VI) can be retained simultaneously. Desorption of selenium species from the sorbents was realized with two different eluents; 0.2% (m/v) KIO3 in 1 M HCl was used for Se(IV) and 2.0 M HCl for Se(VI). The efficiency of the proposed sorbents was demonstrated through spike recovery tests carried out with bottled drinking and tap water samples and the percentage recoveries were found to change between 82.2 ± 7.1 and 109.4 ± 3.6 for Se(IV). For Se(VI), mechanically mixed amino- and mercapto-modified (MIX) silicas in (1:1) ratio has shown the best performance with percentage recoveries of 87.1 ± 3.6 and 74.5 ± 6.6 for the spiked bottled drinking and tap water samples, respectively.

Description

Thesis (Master)--İzmir Institute of Technology, Chemistry, İzmir, 2010
Includes bibliographical references (leaves: 46-49)
Text in English; Abstract: Turkish and English
ix, 49 leaves

Keywords

Chemistry, Kimya

Turkish CoHE Thesis Center URL

Fields of Science

Citation

WoS Q

Scopus Q

Source

Volume

Issue

Start Page

End Page

Collections

Google Scholar Logo
Google Scholar™

Sustainable Development Goals