This is a Demo Server. Data inside this system is only for test purpose.
 

Synthesis of pH-sensitive cholesterol polymers and in vitro investigation of interactions with cell membrane

No Thumbnail Available

Date

2014

Journal Title

Journal ISSN

Volume Title

Publisher

Izmir Institute of Technology

Open Access Color

Green Open Access

Yes

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No

Research Projects

Organizational Units

Journal Issue

Abstract

The aim of this thesis is to synthesize pH-sensitive, cholesterol containing polymers via reversible addition fragmentation chain transfer (RAFT) polymerization, as potential membrane-destabilizing agents for intracellular drug delivery applications and investigate interaction of these polymers with cell membrane. For this purpose, cholesteryl methacrylate (CMA) and 2-((tert-butoxycarbony)(2-((tert-butoxycarbonyl) amino) ethyl) amino)ethyl methacrylate (Boc-AEAEMA) were first synthesized. CMA was copolymerized with t-butyl methacrylate (t-BMA) or Boc-AEAEMA via RAFT polymerization to produce cholesterol containing copolymers having varying molecular weights and compositions. Copolymers were characterized using 1H-NMR spectroscopy and gel permeation chromatography (GPC). Linear increase in ln [M]0/[M] with polymerization time, and Mn with monomer conversion indicated the RAFT-controlled copolymerizations under the conditions tested. P(t-BMA-co-CMA) and P(Boc-AEAEMA-co-CMA) copolymers were hydrolyzed to methacrylic acid-co-CMA (p(MAA-co-CMA) and p(AEAEMA-co-CMA) copolymers, respectively, to obtain water soluble, pH-sensitive copolymers. The pH-responsive behavior of copolymers was demonstrated via UV−visible spectroscopy and dynamic light scattering measurements. These measurements revealed that (p(MAA-co-CMA) copolymers having 2 and 4 mol% CMA form nanoparticles at pH 5.5 while they exist as unimers at pH 7.4. Copolymers having 8% CMA form aggregates at both pH values. Hemolysis assays revealed that p(MAA-co-CMA) having a molecular weight above 20,000 g/mol did not show pH-dependent hemolytic activity regardless of CMA content. The cell viability results (obtained by MTT assay) indicated that p(MAA-co-CMA) at 250 μg/ml concentration is not cytotoxic to NIH3T3 cell line.

Description

Thesis (Master)--Izmir Institute of Technology, Biotechnology, Izmir, 2014
Includes bibliographical references (leaves: 58-61)
Text in English; Abstract: Turkish and English
xii, 65 leaves

Keywords

Biyoteknoloji, Biotechnology

Turkish CoHE Thesis Center URL

Fields of Science

Citation

WoS Q

Scopus Q

Source

Volume

Issue

Start Page

End Page

Collections

Google Scholar Logo
Google Scholar™

Sustainable Development Goals